NAME PRD_QUERY -- query printer port/line status FUNCTION This command returns the status of the printer port's lines and registers. Since the printer port uses either the serial or parallel port for i/o, the actual status returned is either the serial or parallel port's status. IO REQUEST io_Message mn_ReplyPort set if quick I/O is not possible io_Device preset by the call to opendevice io_Command PRD_QUERY io_Data ptr to 2 UBYTES where result will be stored. RESULTS io_Data BIT ACTIVE FUNCTION (SERIAL DEVICE) LSB 0 low reserved 1 low reserved 2 low reserved 3 low Data Set Ready 4 low Clear To Send 5 low Carrier Detect 6 low Ready To Send 7 low Data Terminal Ready MSB 8 high read buffer overflow 9 high break sent (most recent output) 10 high break received (as latest input) 11 high transmit x-OFFed 12 high receive x-OFFed 13-15 reserved io_Data BIT ACTIVE FUNCTION (PARALLEL DEVICE) 0 hi printer busy (offline) 1 hi paper out 2 hi printer selected (WARNING: the bit 2 line is also connected to the serial port's ring indicator pin on the A500 and A2000) 3-7 reserved io_Actual 1-parallel, 2-serial